Discipline
Electrical
Hazardous area classification, Ex protection types, cable selection and sizing, earthing, motors and lighting.
- Topics
- 17
- Standards covered
- 35
Beginner
No prior knowledge assumed
Hazardous areas — zones, gas groups and Ex protection explained
Why a light fitting in a refinery costs ten times a normal one. Zones and divisions, gas groups, temperature classes, IP ratings, and how to read an Ex certification label.
Cables — construction, selection and why sizing is never just about current
What the layers of a cable do, how power, control and instrument cables differ, the four things that decide a cable size, and why the published rating is never the rating you get.
Lighting and small power — the systems people only notice when they fail
How lighting levels are set and why uniformity matters more than average lux, the three tiers of emergency lighting, and why a socket outlet in a hazardous area is not a simple thing.
Intermediate
Builds on the basics
Earthing and bonding — several different jobs sharing one word
Why a plant has more than one earth, the difference between earthing and bonding, how the neutral earthing decision shapes the whole system, and why static bonding has almost nothing to do with fault current.
Motors and starters — starting current, protection and what actually kills them
Why an induction motor draws six times its rated current on starting, what each starting method trades away, and why nearly every motor failure ends as overheated insulation.
Variable speed drives — throttling with electricity instead of a valve
Why slowing a pump saves far more energy than closing a valve, what a VSD does to the motor it drives, the harmonics and bearing currents that arrive with it, and why the cable between drive and motor is not an ordinary cable.
Distribution and the single line diagram — the map of the electrical system
How power gets from the grid to a motor, what transformers and switchgear actually do, why protection must discriminate, and how to trace a supply on a single line diagram.
Emergency power and UPS — what stays alive when the supply does not
The difference between essential and emergency loads, why a UPS and a generator solve different halves of the same problem, what a battery autonomy figure really promises, and why the generator that has never run under load is not a backup.
Switchgear, transformers and protection testing
Why secondary injection proves the relay and primary injection proves everything else, what a reversed CT does to differential and directional protection, why an open CT secondary is dangerous, what breaker timing feeds into, and why phase rotation is checked before anything is paralleled.
Ex installation and inspection — where compliance is actually won or lost
Certified equipment is the easy part. Glands, unused entries, flame paths, IS segregation and the inspection regime are where hazardous area compliance is genuinely decided.
Electrical commissioning and turnover — from dead to live
Why insulation testing needs electronic devices disconnected and readings corrected for temperature, what a functional test proves that a settings check cannot, why an inhibit register exists, why as-left settings are recorded, and what changes the moment a system is energised.
Electrical testing and diagnostics — what each test can actually find
Insulation resistance, polarisation index, tan delta, VLF, partial discharge, contact resistance and thermography. Each one answers a narrow question, most of them are blind to where the defect is, and the order they are done in is set by cost rather than by diagnostic power.
Transformer condition monitoring — reading the oil, not the nameplate
Dissolved gas analysis as a trend rather than a verdict, oil quality and moisture, winding resistance, tap changer condition, the breather nobody changes, and the protection alarms that get bypassed because they are inconvenient.
Protection coordination and grading — why a correct relay can still be wrong
Grading margins, inverse curves, what discrimination actually buys you, and the four routine projects that silently invalidate a protection study without anybody touching a relay setting.
Arc flash and electrical safety — the label, the study behind it, and the work practice
Incident energy and what actually drives it, IEEE 1584 and the limits of a calculation, what an arc flash label does and does not prove, NFPA 70E working practice, and the Indian statutory overlay that sits on top of all of it.
Battery and DC system integrity — the supply that only matters when everything else has gone
Why a battery with the right float voltage can still be dead, impedance trending against timed discharge testing, the unearthed DC system and the first earth fault, duty cycles that grew, and the healthy UPS with a bypass nobody ever proved.
Power quality and harmonics — the drive that damages four things it is not connected to
Where harmonic current actually goes, why a transformer runs hot at half load, the neutral that carries more than the phases, shaft voltage and bearing fluting, and why instrument noise that follows drive speed is an electrical problem.
Standards referenced in this section
- ATEX 2014/34/EU
- CEA Regulations
- EN 12464
- IEC 60034
- IEC 60034-25
- IEC 60076
- IEC 60079-0
- IEC 60079-10-1
- IEC 60079-14
- IEC 60079-17
- IEC 60079-19
- IEC 60079-32
- IEC 60255
- IEC 60364
- IEC 60364-5-52
- IEC 60364-6
- IEC 60502
- IEC 60529
- IEC 60598
- IEC 61439
- IEC 61800
- IEC 61892
- IEC 62040
- IEC 62271
- IEC 62305
- IEEE 142
- IEEE 1584
- IEEE 43
- IEEE 450
- IEEE 519
- IEEE 81
- IEEE 841
- IEEE C57.12.00
- ISO 8528
- NFPA 70E