Mechanical

Non-destructive examination — choosing the method and reading the result

Why every NDE method is blind to something, what magnetic particle cannot do on stainless, why ultrasonics can miss a crack lying the wrong way, the difference between an indication and a defect, and why the examiner's qualification is part of the result.

IntermediateOil & GasPetrochemicalPharmaceutical

Standards referencedASME Section VASME B31.3API 577ASNT SNT-TC-1A

Non-destructive examination looks for what is wrong without taking anything apart. There are half a dozen common methods and the single most useful thing to understand about them is that every one is blind to something.

Choosing a method that cannot see the damage you are worried about is the commonest error in an inspection plan, and it produces a clean report and a false sense of safety.

Non-destructive examination methods and what each one can findSource: ASME Section V for the procedures; ASME B31.3 and API 577 for application
9 rows
Visual (VT)Surface condition, profile, undercut, misalignment, gross defectsAnything below the surfaceAccess, light, and an examiner who knows what good looks like
Penetrant (PT)Surface-breaking flaws in any non-porous materialAnything not open to the surfaceClean surface; works on stainless and other non-magnetic materials
Magnetic particle (MT)Surface and slightly sub-surface flaws in ferromagnetic materialNon-magnetic materials entirely — austenitic stainless, aluminiumA ferromagnetic material, and flaws roughly perpendicular to the field
Ultrasonic thickness (UTT)Remaining wall thickness at the point measuredAnything between measurement points; cracking in most orientationsCouplant, a prepared surface and a known material velocity
Ultrasonic flaw (UT)Sub-surface flaws, including cracks, with depth informationFlaws lying parallel to the beamA qualified examiner; results depend heavily on technique
Phased array (PAUT)Sub-surface flaws, with a steerable beam and a recordable imageLess than conventional UT, but still orientation-dependentHigher examiner qualification and more setup
Radiography (RT)Volumetric flaws — porosity, slag, lack of fusion, and wall lossTight cracks perpendicular to the beamAccess to both sides, an exclusion zone, and radiation control
Eddy current (ET)Surface and near-surface flaws; widely used on exchanger tubesDeep flaws in thick sectionsA conductive material; sensitive to geometry and lift-off
Positive material identification (PMI)What alloy the component actually isEverything about its conditionClean metal surface. Finds the wrong-material errors nothing else will

The column that decides most selections is 'finds'. Every method is blind to something, and choosing one that cannot see the damage mechanism you are worried about is the commonest and most expensive mistake in an inspection plan.

Surface methods

Visual examination is first, cheapest, and consistently undervalued. Profile, undercut, misalignment, arc strikes, surface porosity — a great deal is visible to someone who knows what good looks like. It is also the only method with no equipment between the examiner and the work.

Penetrant draws dye into anything open to the surface, then pulls it back out onto a developer where it can be seen. It works on any non-porous material, which is what makes it the surface method of choice for stainless steel.

Magnetic particle magnetises the part and dusts it with fine particles, which gather where a flaw distorts the field.

Volumetric methods

Ultrasonics sends sound into the material and listens for reflections. Used for thickness, and used for flaw detection, and those are two different jobs.

Radiography passes radiation through the material onto film or a detector. It excels at volumetric flaws — porosity, slag inclusions, lack of fusion — because those remove material the radiation would otherwise have to cross.

Its weakness is the mirror image of ultrasonics. A tight crack perpendicular to the beam removes almost no material in the direction of travel, so it may produce no image at all.

Thickness surveys are blind to cracking

A thickness reading tells you how much metal remains at that spot. It is the right tool for general wall loss and it is the basis of remaining life.

It is close to useless against cracking. A crack can run through a wall that measures full thickness a few millimetres either side, because it removes almost no material.

That is the same point the risk-based inspection topic makes from the other direction: naming the damage mechanism is what decides the technique.

Indication, or defect?

Cross-sections through welds showing porosity, slag inclusion, lack of fusion, lack of penetration, undercut and a crack, each labelled.
Each of these presents differently to each method. Porosity and slag show clearly on radiography; the crack may not show at all unless the beam catches it.

The examiner is part of the result

Some methods are close to objective. Radiography produces a film that another person can look at next year.

Ultrasonics does not. Beam angle, scanning pattern, couplant, calibration and interpretation all sit with the person holding the probe, and two competent examiners can reach different conclusions on the same weld.

Positive material identification

PMI answers a different question from all of the above: is this component the alloy it is supposed to be?

It finds nothing about condition and everything about identity — the 316 fitting that is actually 304, the alloy elbow replaced with carbon steel during a shutdown. Those errors are invisible to every other method on this page, and they fail in service by corroding far faster than the line around them.

What to take away

  • Every method is blind to something. Match the method to the damage mechanism, not to availability.
  • MT does nothing on austenitic stainless. Use penetrant for surface flaws on non-magnetic material.
  • UT can pass over a crack lying parallel to the beam; RT can miss a tight crack perpendicular to it. They are complements.
  • Thickness surveys are blind to cracking.
  • An indication is not a defect until the acceptance criteria say so — and unnecessary repairs carry their own risk.
  • For interpretive methods the examiner’s qualification is part of the result.
  • PMI finds the wrong-material errors nothing else will.

Check your understanding

6 questions. Nothing is recorded — this is just for you.

1Magnetic particle examination is specified on an austenitic stainless steel weld. What is the problem?
2Why can ultrasonic examination miss a crack that is genuinely there?
3What is the difference between an indication and a defect?
4Radiography is proposed to find stress corrosion cracking. What is the concern?
5Why does a thickness survey give no protection against cracking mechanisms?
6Why is the examiner's qualification part of the examination result?

#mechanical#nde#ndt#inspection#welding#quality